● Open protocol for software self-programming.
● AC voltage sources: 3x900V@3x25VA, accuracy 0.05%.
● AC current sources: 3x30A@3x25VA, accuracy 0.05%.
● 3-phase Harmonic Standard Power: 2-31x orders with 0.1 % accuracy.
● DC voltage sources: 825V@20W max, accuracy 0.05%.
● DC current sources: 30A@25W max, accuracy 0.05%.

● 3-years guarantee of free repair, and life-long maintenance, Free software update and training.

KS813 Three-phase AC and DC Calibrator
Description
Specifications
Advance Feature
Ordering Instruction

Basic Functions

  • Applied to Grid Corporation of measurement testing centers, power companies and power plants measured ministries, national institutions at all levels of measurement tests, also applies to the railway, petroleum, chemical industry, large-scale industrial and mining enterprises and the meter manufacturers, etc.

  • Apply to the power sector, measurement department, quality inspection departments, research institutions, universities, etc.

  • Applies to other production and research & development enterprise of energy meter, power distribution terminals, power management, load control, power quality, and medium voltage reactive power compensation.

  • Open communications protocol to facilitate the secondary development for RTU / FTU / Power Management Terminal / Public variable measuring the terminal factory automatic verification.

  • Calibrating a variety Analog Digital meter of direct U/I instruments & frequency with DC/AC 0.05% accuracy and the corresponding class digital multimeter for quality inspection, measurement and instrumentation maintenance, parts detection.

  • The calibrating types of test instrument including AC-DC voltage meter, ammeter, single / three phase active and reactive power meter, phase meter, power factor meter, frequency tables, synchronized tables, etc.

  • The calibrating transducer types are AC-DC voltage transducer, current transducer, single / three phase active and reactive power transmitter, phase transmitter, power factor transducer, frequency transducer, etc.

  • The calibrating energy meter types as electronic and sensing single-phase, three-phase active and reactive energy meter.

  • Storage capacity up to 1,000 calibrated meters' data.

  • 5.4" TFT LCD display, touch pad and rotary encoder control, PC control software also available.


Comprehensive Guide to Phase Calibrator:

Power Calibrator Guardian of Efficiency


Output & Measuring AC Voltage
Available Ranges10V, 30V, 100V, 300V, 750V, auto-shift
Adjustment range0~120%Rg
Adjustment finenessRange x 0.01%
ResolutionRange x 0.01%
Accuracy0.05%Rg
Stability0.01% / 1min
Output & Measuring AC Current
Available Ranges100mA, 1A, 5A, 10A, 25A; auto-shift
Adjustment range0~120%Rg
Adjustment finenessRange x 0.01%
ResolutionRange x 0.01%
Accuracy0.05%Rg
Stability0.01% / 1min
Output & Measuring AC Power
Adjustment finenessRange x 0.01%
ResolutionRange x 0.01%
Accuracy0.05%Rg (Factor>0.5)
Stability0.01% / 1min
Output & Measuring AC Frequency
Frequency Range45.000~65.000Hz
Adjustment fineness0.001Hz
Accuracy0.01%RD
Output & Measuring AC Phase Angle
Phase Angle Range0.00º~359.99º
Adjustment fineness0.01º
Resolution0.01
Accuracy0.05º
Output & Measuring AC Power Factor
Output Range-1 ~ 0 ~ +1
Measuring Accuracy0.0005
Adjustment fineness0.0001
Output & Measuring Harmonic
Harmonic Setting2~31
Harmonic Contentvoltage, current ≤30% (as against fundamental)
Harmonic Output Accuracy0.1% (1st~19th, as against fundamental)
0.2% (20th~31st, as against fundamental)
Harmonic Phase0~360º, adjustable
Measuring Electrical Energy
Measuring Accuracy0.1%Rd, PF≥0.5
Voltage Range100V, 220V, 380V
Current Range0.05~24A
Distortion of AC Outputs
Distortion<0.2% (non-capacitance load)
Max Load Capacity of AC Voltage & Current
Voltage Output25VA max
Current Output25VA max
Output & Measuring DC voltage
Range100mV, 1V, 10V, 30V, 100V, 300V, 750V
Adjustment Range0~120%Rg, (0%~110% output range at 750V)
ResolutionRange x 0.01%
Accuracy0.05%Rg
Stability0.01% / 1min
Output & Measuring DC current
Range1mA, 10mA, 100mA, 1A, 5A, 10A, 25A
Adjustment Range0~120%Rg
Adjustment finenessRange x 0.01%
ResolutionRange x 0.01%
Accuracy0.05%Rg
Stability0.01% / 1min
Max Load Capacity of DC Voltage & Current
Voltage Output20W max
Current Output25W max
Power Supply & Environment
Ambient Temperature22ºC ± 1ºC
Working Temperature0ºC~40ºC, humidity≤85%RH
Nominal Input Voltage115/230Vac appointed, ±10%
Nominal Frequency50/60Hz
Connection TypeStandard AC socket 60320
Weight & Size
Dimensions(W x D x H)450mm×380mm×190mm
Weight25kg


KS813 Standard Source is fully compatible with the relevant national standards:

  • JJG124-93 Verification Regulation of Ammeter, Voltmeter & Ohmmeter.

  • GB/T767-1999 Direct Acting Indicating Analogue Electrical Measuring Instruments & Accessories.

  • SD110-83 Inspection Regulation of Electrical Indicating & Measuring Instruments.

  • JJG440-86 Verification Regulation of Frequency Single Phase Meters.

  • JJG603-89 Verification Regulation of Pointer Frequency Meters.

  • JJG 307 -1998 Verification Regulation of Verification Equipment for AC Electrical Energy Meter.

  • JJG596-1999 Verification Regulation of Electrical Energy Meters.

  • GB/T 11150-2001 National Standard of Electrical Energy Meter Inspection Instruments.

  • JJG (Power) 01-94 Verification Regulation of Electrical Measuring Transducers.


KS803KS813KS823KS833
AC Standard Source
Harmonic Source
Power Standard Source
DC Standard Source
Instrument Calibration
Energy Meter Calibration
Transducer Calibration
√: With the corresponding function modules;
○: Without the corresponding function modules.