● Powerful 6-phase protection relay tester and commissioning tool, convenient for field test;
● 6x35A & 4x310V high accuracy analog channels output;
● 9.7" True color TFT LCD, touch screen and keyboard operating, w/wo laptop control;

● The ever-expanding test library templates.

Feel free to explore our range of protection relay test set.

digital earth leakage relay
secondary injection test for protection relay
relay test unit
Description
Specifications
Ordering Instruction
Video

Basic Functions

  • Universal Relay Test Applications.

  • Inbuilt 9.7" True color TFT LCD with touch screen, numerical and shortcut keyboard, fully control with/without laptop.

  • 10 Channels (6x35A & 4x310V) outputs, Each output channels are independent and simultaneous control of magnitude, Phase angle and frequency values, able to inject DC, AC sine wave and up to 60x harmonics.

  • Variable battery simulator, DC 0-350V, 140Watts max.

  • Transient play back up to 3KHz.

  • Fully function KRT software testing modules.

  • Graphical test modules and templates for testing of various relays.

  • Quick relay testing facility in Manual mode.

  • Shot/Search/Check, Point & Click testing.

  • RIO/XRIO import & export facility.

  • Switch on to fault test(SOTF).

  • Power system model for dynamic testing.

  • Online Vector display.

  • Automatic test results assume.

  • Automatic test report creation.

  • Inbuilt GPS sync end-to-end testing.

  • Anti-clipping detect, Wrong wiring connect alarm and self-protect, overload and overheat protection.

  • 3-Years guarantee of free repair and life-long maintenance.

  • Lightweight, <20Kg.

  • Free software upgrade.


Advance Feature

  • Energy meter calibration (Mechanical & Electronic meters).


Type of Relays Can Be Tested

ItemsANSI® No.
Distance protection relay21
Synchronising or synchronism-check relays25
Undervoltage relays27
Directional Power relays32
Undercurrent or underpower relays37
Negative sequence overcurrent relays46
Overcurrent/ground fault relays50
Inverse time overcurrent/ground fault relays51
Power factor relays55
Overvoltage relays59
Voltage or current balance relays60
Directional overcurrent relays67
Directional ground fault relays67N
DC overcurrent relays76
Phase-angle measuring or out-of-step protection relays78
Automatic reclosing devices79
Frequency relays81
Motor overload protection relays86
Differential protection relays87
Directional voltage relays91
Voltage and power directional relays92
Tripping relays94
Voltage regulating relays
Overimpedance relays, Z>
Underimpedance relays, Z
Time-delay relays


Voltage Outputs
Output Range & Power4×310 V ac (L-N)124 VA max each
3×350 V dc (L-N)140 W max each
Accuracy<0.02%Rd+0.005Rg Typ.
<0.05%Rd+0.01Rg Guar.
±10mV @ <5V dc
±0.5% @ ≥5V dc
Voltage RangeRange I: 30V
Range II: 310V
Automatic Range
DC Offset<10mV Typ./ <60mV Guar
Resolution1mV
Distortion<0.015%Typ. / <0.05% Guar.
Current Outputs
Output Range & Power6×35A ac (L-N)450 VA max each
3×70A ac (2L-N)850 VA max each
1×100A ac (6L-N)1200 VA max
3×20A dc (L-N)300W max each
Accuracy<0.03%Rd+0.02Rg Typ.
<0.1%Rd+0.05Rg Guar.
±5mA @ <1A dc
±0.5% @ ≥1A dc
Current RangeRange I: 3A
Range II: 35A
Automatic Range
DC Offset<3mA Typ./ <10mA Guar
Resolution1mA
Distortion<0.025%Typ. / <0.07% Guar.
Frequency & Phase Angle
Frequency RangeDC~1KHz, 3KHz transient
Frequency Accuracy±0.5ppm
Frequency Resolution0.001 Hz
Phase Range-360°~360°
Phase Accuracy<0.02° Typ. / <0.1° Guar. 50/60Hz
Phase Resolution0.001°
Aux. DC Voltage Source (Battery simulator)
Range0~350V @ 140W max
Accuracy0.5%Rg Guar.
Binary Input
Quantity8pairs
Typewet/dry, up to 300Vdc max input
Time resolution10us
Sampling Rate10KHz
Debounce time0~25ms (Software Controlled)
Time rangeInfinite
Time errors±1ms @ ≤1s, ±0.1% @ >1s
Galvanic isolationIsolated each pairs
Binary Output (Relay Type)
Quantity4pairs
TypePotential free relay contacts, software controlled
Break Capacity ACVmax: 400Vac / Imax:8A / Pmax:2500VA
Break Capacity DCVmax: 300Vdc / Imax:5A / Pmax:150W
Binary Output (Semiconductor Type)
Quantity4pairs
Type:Open-collector, Combination type male
Break Capacity DC5~15Vdc / 5mA, 10mA max
Response time:100us
Synchronization
Synchronization Mode GPS, SMA type antenna connector
Power Supply & Environment
Nominal Input Voltage110V/220/230V ac, Appointed
Permissible Input Voltage85~264Vac, 125~350VDC, auto-protective
Nominal Frequency50/60Hz
Permissible Frequency45Hz~65Hz
Power Consumption1500 VA max
Connection TypeStandard AC socket 60320
Operating Temperature-10℃~55℃
Storage Temperature-20℃~70℃
Humidity<95%RH, non-condensing
Others
PC ConnectionRJ45 Ethernet, 10/100M
USB port2 USB type-A ports for external Keyboard, mouse or Data transport
Grounding Terminal4mm banana socket
Weight20 Kg
Dimensions(W x D x H)480×320×160(mm)


ModelCurrent OutputsVoltage Outputs
K2066i6×35A @ 450VA max
3×70A @ 850VA max
7×310V @ 90VA max
K2063i6×35A @ 450VA max
3×70A @ 850VA max
4×310V @ 124VA max
K2030i3×35A @ 450VA max4×310V @ 124VA max


KINGSINE K2063i Protection Relay Tester Shake Test



KINGSINE K2063i Over Range Power Supply Test


GET IN TOUCH WITH KINGSINE
Whether you have a question about KINGSINE Electrical Testing Devices or anything else, we're here to help and ready to answer your questions.
E-mail
inquiry@kingsine.com
Call Us
+86-0755-8835-2631
Headquarter
6C/F4.8 TianAn Cyber Park, Futian, Shenzhen, 518040, China
Contact Us