Kingsine Electric Automation Co.,Ltd.
Kingsine Electric Automation Co.,Ltd.
Email Us

KINGSINE EngyBrick Distributed Intelligent Power Monitoring Module

EngyBrick System is about smart power distribution modules solution, which are dedicated to assisting clients improving their working efficiency and greatly reducing their asset purchase budget and installation cost, providing users the best convenient installation mode and the best time-saving commissioning mode. The system consist of communication signal acquisition&voltage monitoring, current monitoring two parts. The system adopt independent bus power supply mode, RJ45 port connecting with each component modules. Its commissioning adopts one-key mode for address configuration in the field. It also can configure the parameters and the module working mode via the display screen.

power monitoring module
energy meter module
Description
Specification

Advantage

● Modular design, Din-rail installation, suit for compact and dense distribution transformation installation environment.

● Current transformer use external connection mode(Split core or Non-split core optional), convenient for maintain.

● Easy installation and testing, reduce work intensity and work time.

● Standard port for create network wire connection,save auxiliary costs.

● It can realize full power monitoring on electric distribution circuit and 2-31 harmonic monitoring.

● EBT12 are split-core type current transformers in design, which can realize online installation without power off, and energy accuracy is of 0.5%.

● The module is of small size so that the monitoring point is installed nearby.

● Din-rail amount design, easy installation and shortened construction period.

● Suitable for multi-point central monitoring deployment.


Application

● Industrial Distribution Automation System.

● Energy Management System.

● Substation Automation System.

● Intelligent Building Electrical Engineering.

● Power plant auxiliary power system.

● High and low voltage switch-gear.

Communication & Voltage Moitoring

ModuleEBUC10
MeasurementU12, U23, U31 V1, V2, V3, f
THD v1, THD v2, THD v3
voltage harmonic
Power supplyIndependent bus power supply
Module typeEBUC10 module
Alarm


Current monitoring

ModuleModule+CT
MeasurementI1, I2, I3, P, Q, S, PF, f
Max/Min. valueI, ΣP, ΣQ, ΣS, ΣPF, THD I
Power supplyIndependent bus power supply
Module typeEBI12 module
Current transformer5A, 50A, 200A, 400A, 600A, 800A, 1000A……
Alarm


Hareware Configuration List Equivalent of one 3 Phase Power Meter

Item No.Module NameModelUnitQuantityRemark
1Communication& Voltage ModuleEBUC10piece1
2Power Supply ModuleEBP10piece1
3Current ModuleEBI12piece1
4Current transformer modulesEBT12piece3Triple times the number of current modules


Note: When it requires increase the monitoring power meter, then user only need to increase the current module and current transformer module. That one EBUC10 and one EBP10 can maximum master 32 pieces of EBI12 which equivalent to 32 pcs of three-phase power meter.

Technical Specification

Measurement Accuracy
Measurement CharacteristicsAccuracy
Active Energy0.5 %
Reactive Energy1.0 %
Apparent Energy0.5 %
Active Power0.5 %
Reactive Power1.0 %
Apparent Power1.0 %
Power Factor0.5 %
Voltage Measurement0.2 %
Current Measurement0.2 %
Voltage Harmonics±0.5 %
Current Harmonics±0.5 %
Frequency0.05Hz


Voltage Measurement
Voltage Measurement50-300VAC(ph/N)
87-520VAC(ph-ph)
Measure TypeSingle phase/Three phase four wires/Three phase three wires
Frequency measurement45-65Hz


Communication Characteristics(EngyBus)
Modules wire cableRJ45 net cable, Use 586 line order
ProtocolModBus RTU
Speed Rate1200-115200 band-rate
Power supply24V Centralize Bus Power supply


Mechanical Characteristics
Installation MethodDin-rail or back side installation
Protection LevelIP40
Size64.2mm*89.3mm*18mm


Communication & Voltage Module Instruction

EBUC10 Communication & Voltage Module


EBUC10 Communication & Voltage Module

Item No.NameDescription
1Communication portCoftware upgrade
2Power supply indicatorWorking status display
3Communication indicatorCommunication status display
4Alarm indicatorSystem alarm
5WiFi  indicatorWiFi status display
6ButtonContinuously press for 3 secs to auto configure the address


Working surroudings
1Working temp.:-25℃ ~ +70℃
2Storage temp.:-40℃ ~ +85℃
3Humidity:5% ~ 95%RH, No condense
4Devices should be installed in suitable electrc isolated and fireproof boxes


EBI11 Current Module


EBI11 Current Module

Item No.NameDescription
1Communication portSoftware upgrade
2Power supply indicatorWorking status display
3Communication indicatorCommunication status display
4Alarm indicatorSystem alarm
5Pulse indicatorLoad Pulse display
6ButtonContinuously press for 3 secs to auto configure the address


Working surroudings
1Working temp.:-25℃ ~ +70℃
2Storage temp.:-40℃ ~ +85℃
3Humidity:5% ~ 95%RH, No condense
4Devices should be installed in suitable electrc isolated and fireproof boxes


GET IN TOUCH WITH KINGSINE
Whether you have a question about KINGSINE Electrical Testing Devices or anything else, we're here to help and ready to answer your questions.
E-mail
inquiry@kingsine.com
Call Us
+86-0755-8835-2631
Headquarter
6C/F4.8 TianAn Cyber Park, Futian, Shenzhen, 518040, China
Contact Us